Warranty: 18 Month
Accuracy: ±0.6-1%
Size: DN50-DN300
Sensor: Tube/Flange
Application: Industrial Production
Type: Ultrasonic Flow Meter
Samples:
US$ 29/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
F4713
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Connection
Flange
Material
Wcb/SS304/SS316
Protect Gread
IP68
Power
Electric
Transport Package
Wooden Case
Specification
DN50-DN300
Trademark
OEM
Origin
China
HS Code
9026100000
Production Capacity
30000/Month

Product Description

1.Product overview:
Ultrasonic water meter is developed based on ultrasonic measurement of propagation velocity difference method. An ultrasonic signal is emitted to the fluid through the sensor,  An instrument that transmits an ultrasonic signal through a sensor to a fluid and then receives the ultrasonic signal after it is affected by the flow of the fluid and applies the result to a flow measurement. The instrument integrates measurement, integration and display, and adopts micro-power consumption technology, can achieve the minimum flow 0.0125 accurate measurement, At the same time, the instrument has the characteristics of small volume, good stability and strong anti-interference ability. Ultrasonic flow measurement technology can realize multi-angle installation, the instrument measurement is not affected, and the pipeline pressure loss is minimized.The product conforms CJ/T 434-2013 to the standard of ultrasonic water meter.Flow Meter/Ultrasonic Flow Meter/Liquid Meter/Ultrasonic Water MeteFlow Meter/Ultrasonic Flow Meter/Liquid Meter/Ultrasonic Water Mete
2.Technical parameters:

(1)Range of flow:
The inner diameter of the pipe Q3/Q1 Q2/Q1      Minimum flow(Q1)
 
Flow at the boundary
(Q2)
 
Frequently used flow(Q3)
 
Overloaded flow 
(Q4)
 
DN50 100 1.6 0.25 0.4 25 31.25
DN65 100 1.6 0.4 0.64 40 50
DN80 100 1.6 0.63 1.008 63 78.75
DN100 100 1.6 1 1.6 100 125
DN125 100 1.6 1.6 2.56 160 200
DN150 100 1.6 2.5 4 250 312.5
DN200 100 1.6 4 6.4 400 500
Medium under test Water, and fill the pipes under test
Accuracy level Level 2
Nominal diameter DN50-DN200
Maximum working pressure 1.6
Display contents Instantaneous flow rate  Cumulative flow
Display resolution Instantaneous flow rate 0.001
  

  Cumulative flow 0.01
(They can be adjusted by software)
Display range Cumulative flow:0-999999.99
Data communication protocol Cj-T188  485- MODBUS agreement(Optional)
Data storage Data is stored in real time, and it will be protected by power failure
Working power supply 3.6V lithium battery
(2)Size of structure
DN50~DN200 are made of carbon steel and connected by flange.         
Nominal pressure:1.6Mpa
Nominal diameter

(mm)
Length of pipe section
L(mm)
Width of flange surface
D( mm )
Height of pipe section
(mm)
Bolt diameter
×number
N - Ø
Diameter of sealing surface
D2( mm )
Thickness of flange

C(mm)
50 200 165 125 18×4×2 99 15
65 200 175 170 18×4×2 117 15
80 220 185 185 18×8×2 132 15
100 250 220 180 18×8×2 156 18
125 250 230 230 18×8×2 184 18
150 300 285 240 22×8×2 211 18
200 350 340 295 22×12×2 266 20
3.Installation precautions:
The installation of pipe sections should meet the following conditions:
Avoid installing machines in places where water pumps, high-power radios, and frequency conversions are located. That is, avoid installing the machine where there is strong magnetic field and vibration interference.
The pipe should be uniform and dense, and the pipe section that is easy for ultrasonic transmission.
The installation point of the upstream straight pipe section must be greater than 10D (Note: D=diameter), and the installation point of the downstream straight pipe section must be greater than 5D (see the figure below).
The upstream installation point should be 30D away from the pump.
The fluid should fill the pipe.
There should be enough space around the pipeline to facilitate the operation of on-site personnel.
4.Design and function
transducer: the main signal generating module, using imported piezoelectric ceramic which guarantee the stable function, consistency and high precise measurement.
temperature sensor: using pt-100 high precise platinum resistance and measurement circuit of high precision is also equipped for better measurement.
self diagnosis function: if communication errors, low battery or intentional damage is detected in the working process of ultrasonic heat meter, the system will display the errors in relating code and malfunction will be seen in the top right corner of the screen. all the data will be stored automatically and switch back after the malfunction is eliminated.
nice appearance, capable of being hanged in all four directions. easy to read and operate.
easy to install. dust-proof, moisture-proof, water-proof, anti-disassembly, better prevention of vandalism.
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 9000