Customization: | Available |
---|---|
Warranty: | 18 Month |
Accuracy: | ±0.6-1% |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The inner diameter of the pipe | Q3/Q1 | Q2/Q1 | Minimum flow(Q1) |
Flow at the boundary (Q2) |
Frequently used flow(Q3) |
Overloaded flow (Q4) |
|
DN50 | 100 | 1.6 | 0.25 | 0.4 | 25 | 31.25 | |
DN65 | 100 | 1.6 | 0.4 | 0.64 | 40 | 50 | |
DN80 | 100 | 1.6 | 0.63 | 1.008 | 63 | 78.75 | |
DN100 | 100 | 1.6 | 1 | 1.6 | 100 | 125 | |
DN125 | 100 | 1.6 | 1.6 | 2.56 | 160 | 200 | |
DN150 | 100 | 1.6 | 2.5 | 4 | 250 | 312.5 | |
DN200 | 100 | 1.6 | 4 | 6.4 | 400 | 500 | |
Medium under test | Water, and fill the pipes under test | ||||||
Accuracy level | Level 2 | ||||||
Nominal diameter | DN50-DN200 | ||||||
Maximum working pressure | 1.6 | ||||||
Display contents | Instantaneous flow rate Cumulative flow | ||||||
Display resolution | Instantaneous flow rate 0.001 Cumulative flow 0.01 (They can be adjusted by software) |
||||||
Display range | Cumulative flow:0-999999.99 | ||||||
Data communication protocol | Cj-T188 485- MODBUS agreement(Optional) | ||||||
Data storage | Data is stored in real time, and it will be protected by power failure | ||||||
Working power supply | 3.6V lithium battery |
Nominal diameter (mm) |
Length of pipe section L(mm) |
Width of flange surface D( mm ) |
Height of pipe section (mm) |
Bolt diameter ×number N - Ø |
Diameter of sealing surface D2( mm ) |
Thickness of flange C(mm) |
50 | 200 | 165 | 125 | 18×4×2 | 99 | 15 |
65 | 200 | 175 | 170 | 18×4×2 | 117 | 15 |
80 | 220 | 185 | 185 | 18×8×2 | 132 | 15 |
100 | 250 | 220 | 180 | 18×8×2 | 156 | 18 |
125 | 250 | 230 | 230 | 18×8×2 | 184 | 18 |
150 | 300 | 285 | 240 | 22×8×2 | 211 | 18 |
200 | 350 | 340 | 295 | 22×12×2 | 266 | 20 |